Model NO.: WXL-1500A-940-2
Customized: Customized
Condition: New
Product Name: Fume Cupboard
Worktop: 1426*802*791 Mm
Input Power: 220V/50-60Hz
Face Velocity: 0.4-0.6
Application: Office Building, Hospital, School, Laboratory
Base Material: PP
Faucet: UPVC
Transport Package: Standard Export Wooden Case Packing
Specification: 1500*940*1940 Mm
Trademark: Ample
Origin: Chengdu, China
HS Code: 8414809090
Supply Ability: 200 Set/Month
Material: PP
Type: Bypass Type
Function: Exhaust, Velocity Control
Feature: Corrosion Resistance, Heat Resistant, Acid & Alkali Resistant, Fireproof, Explosion Proof
Hood Type: Standard
Color: White
Customization: Available | Customized Request
Product Description

Product Description

Company Info.

Customer Question & Answer
Ask something for more details

  • Overview
  • Product Description
  • Product Parameters
  • Our Advantages
  • Detailed Photos
  • Application Cases
Overview

Basic Info.

Model NO.
WXL-1500A-940-2
Customized
Customized
Condition
New
Product Name
Fume Cupboard
Worktop
1426*802*791 mm
Input Power
220V/50-60Hz
Face Velocity
0.4-0.6
Application
Office Building, Hospital, School, Laboratory
Base Material
PP
Faucet
UPVC
Transport Package
Standard Export Wooden Case Packing
Specification
1500*940*1940 mm
Trademark
Ample
Origin
Chengdu, China
HS Code
8414809090
Production Capacity
200 Set/Month

Product Description

Product Description

Ductless fume hoods protect your personnel and the environment from toxic or volatile chemicals so that you can concentrate on what matters most: your work. Continuous airflow across the work surface draws contamination away from the user, recycling clean air back into your laboratory. Our ductless fume hoods provide energy savings, safety and convenience and are available in a variety of configurations, including mobile fume hoods and polypropylene fume hoods.

  • Compliance to ASHRAE 110 for superior fume containment
  • Effective carbon filtration efficiency
  • Easy-to-use control system with alarms for unsafe conditions
  • Wide selection of carbon filter types to accommodate a variety of chemical handling
  • Plug-and-play feature which prevents any laboratory downtime
  • Offers a broad range of accessories and options
  • Industry-unique dual diffuser system that helps optimize carbon filter life
  • Energy-efficient design which reduces total carbon footprint
  • Must be mobile, portable, and easily relocated
Product Parameters
                Model Specification  WJ-1500AWJ-1500BWJ-1800AWJ-1800B
External dimensions of equipment(mm)1500(W)*1205 (D) *2400 (H)1800(W)*1205 (D) *2400 (H)
Dimension of works pace (mm)1260(W1)*780(D1) *1100 (H1)1560(W1)*780(D1) *1100 (H1)
Panel material20+6mm thick butterfly ceramics
Material of internal lining board5mm thick ceramic fiber board
Diversion structureLower air return
Control systemButton control panel (LCD panel)
PH value controlThe medium is alkaline water solution; manual monitoring, and manual control through acid pump and alkali pump.
Input powerThree-phase five-wire 380V/50A
Current for air fanNot over 2.8A(380V or 220V can be directly connected)
Maximum load of socket12 KW(total of 4 sockets)
Water tap1 set (remote control valve water nozzle)No1 set (remote control valve + water nozzle)No
Water discharge wayMagnetic chemical pump strong discharge
Using environmentFor non-explosion indoor use, within 0-40 degrees Celsius.
Applicable fieldsInorganic chemistry experiment; Food, medicine, electronics, environment, metallurgy, mining, etc.
Ways of PurificationSpray sodium hydroxide solution, no less than 8 cubic meters/hourSpray sodium hydroxide solution.no less than 12 cubic meters/ hour
Ways of surface air speed controlManual control (through the electric air valve to adjust the exhaust air volume or adjust the height of the moving door)
Average surface air speed0.6-0.8 m/s Exhaust air volume: 1420-1890m3/h (when door height h =500mm)0.6-0.8 m/s Exhaust air volume: 1760-2340m3/h (when door height h =500mm)
Speed deviation of surface airNot higher than 10%
The average intensity of illuminationNot less than 700 Lux; Standard white and uv-free yellow LED lamps; The illumination is adjustable.
NoiseWithin 55 decibels
Flow displayWhite smoke can pass through the exhaust outlet, no overflow.
Safety inspectionNo spikes, edges; Charged body and the exposed metal resistance is greater than 2 mQ; Under 1500V voltage, no breakdown or flashover occurred for 1min test.
Resistance of exhaust cabinetLess than 160 pa
Power consumptionLess than 1.0kw/h (excluding power consumption of fans and external instruments)Less than 1.2kw/h (excluding power consumption of fans and external instruments)
Water consumptionLess than 3.2L/ hLess than 4.0L/ h
Performance of wind compensationWith a unique wind compensation structure, the volume of the wind will not cause turbulence in exhaust cabinet and will not directly blow to the staff (need to connect to the air compensation system of the laboratory)
Air volume regulating valve315mm diameter flanged type anti-corrosion electric air flow regulating valve (electric contact actuator)
 
Our Advantages

Advanced ductless carbon filtration technology offers a safe, high performance alternative to conventional ductless fume hoods for a broad range of applications.

  • Environmental Benefits. Air Science ductless fume hoods isolate and trap chemical vapors to prevent ecological impact through release into the environment.
  • Versatile. Each filtration system is selected for its specific application. The Multiplex Filter broadens the range of applications. Carbon filters are available in more than 14 configurations for use with vapors or organic solvents, acids, mercury and formaldehyde. HEPA/ULPA filters can add to biological safety.
  • Easy to Install. Fume hoods are self-contained and do not require venting to the outside. Many units are portable and may be moved from one location to the next with minimal downtime and without filter changes. Set-up, operation and filter maintenance are straightforward.
  • Energy Efficient. Because filtered air is returned to the room, no demands are required of the facility HVAC capacity for make-up air.
  • Cost Effective. Facility ductwork, HVAC and construction costs are eliminated.
  • Safe to Use. Cabinet airflow and face velocity protect users from incidental exposures to fumes.
  • Self testing. (selected models) Electronic airflow monitoring assures continuous safety. An electronic gas sensor monitors carbon filter performance.
Detailed Photos

Laboratory Equipment Ductless Fume Hood Clean Use for School
Laboratory Equipment Ductless Fume Hood Clean Use for School
Laboratory Equipment Ductless Fume Hood Clean Use for School

Application Cases

Inside the fume hood, there are facilities to let you work. For example, there is almost always some good lighting system in the cabinet. There should be LPG and water connections in the hood, and a drain too in case of spills. 

The air suction system is generally placed on top of the box or on the backside (the side towards the wall). This system is generally made up of a strong exhaust fan or air pump and accompanying air duct. The strength of the pump lies in the airflow strength starting from 4 to 8 meters per second to more. 

When the exhaust is running, it sucks in volumes of air through the open side (never run the exhaust with the hood completely closed) and vents it through the duct. The duct may throw the fumes right outside the room in the air, or may run it through a filtration system, depending upon the severity of the experiment.

Some advanced laboratory fume hoods have microcontrollers inside them, which you can use to control the exhaust. You may set various suction levels for given setups and later use these quick setups for particular experiments. You can also control the fan/pump power during the experiment too, and the lights as well. The control panel can also warn you about various inconsistencies, like the presence of smoke or fire or too high a shutter

Laboratory Equipment Ductless Fume Hood Clean Use for School
Laboratory Equipment Ductless Fume Hood Clean Use for School

 
Recommended Products
Get in touch with us
Tel : +86 13589271654
Characters Remaining(20/3000)